MASTER FEED
6.5.2 AUTO ADJUSTABLE MASTER SET
(1)
[A]
[B]
When the customer installs a master roll in the master making unit, the machine
automatically adjusts the position of the leading edge of the master.

Procedure

The duct plate moves to the open position [A] from the middle position. (1)
The master vacuum fans [B] turn on. (1)
The master vacuum fans turn on after 2.0 seconds. The master feed motor feeds
the master 40 mm when the master edge sensor [C] does not detect the master.
(2-1)
If the master edge sensor detects the master, the master feed motor does not feed
the master. (2-2)
The master feed motor reverses the master until the master edge sensor does not
detect the master. (3)
The master feed motor feeds the master until the master edge sensor detects the
master. (3)
The duct plate moves to the middle position [D] from the open position. (4)
The master vacuum fans turn off. (4)
C267
(2-1)
[C]
(2-2)
6-18
(3)
[D]
(4)