Administer The Bus Bridge; Test The Packet Bus And C-Lan Circuit Pack; Resolve Alarms; Enable Alarm Origination To Inads - Avaya CMC1 Installation, Upgrades And Additions

Table of Contents

Advertisement

Adding or Removing Hardware

Administer the Bus Bridge

1. Type change system-parameters maintenance and press Enter.
2. On Page 2, Type y in the PKTINT 2 field.
3. Choose the port bandwidths or use the default and submit the form.
4. Verify the bus bridge LED is lit on the TN799DP C-LAN circuit pack. This indicates that the
packet bus is enabled.

Test the Packet Bus and C-LAN Circuit Pack

Type test packet port-network 1 long and press Enter. For more
detail about these tests, refer to the test pkt command section in the Maintenance for Avaya
DEFINITY Server CSI.

Resolve Alarms

Examine the alarm log. Resolve any alarms using Maintenance for Avaya DEFINITY Server
CSI.

Enable Alarm Origination to INADS

1. Ask the regional Customer Software Administration to complete the
Options
steps. See
Note:
As part of the system registration process, the INADS Database Administrator
Note:
enables Alarm Origination and customer options.

Verify Customer Options

To verify customer options:
1. Type display system-parameters customer-options and press Enter.
Ensure that the G3 version field is V11.
2. If the customer was using Supplementary Services Protocol b or d on an ISDN-PRI trunk
group before the upgrade, go to the QSIG Optional Features screen and ensure that the
Basic Call Setup field is y.
270 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
Where to get additional help
Verify Customer
on page 22 for telephone numbers.