Technical Data - ESAB Caddyt Arc 150i Service Manual

Hide thumbs Also See for Caddyt Arc 150i:
Table of Contents

Advertisement

TECHNICAL DATA

Mains voltage
Fuse (delayed- -action)
Primary current I
max
Primary current I
eff
Voltage/current range
(TIG)
(MMA)
Maximum permissible load at TIG
35% duty cycle
60% duty cycle
100% duty cycle
Maximum permissible load at MMA
25% duty cycle
35% duty cycle
60% duty cycle
100% duty cycle
Power factor at maximum current
Efficiency at maximum current
Open- -circuit voltage
Open- -circuit voltage Caddy Arc VRD
Operating temperature
Constant A- -weighed sound pressure
Dimensions, l x b x h
Weight
Enclosure class
Application class
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
ct27d1
CaddyTig 150
CaddyArc 150
230 V ±10% 1∼ 50/60 Hz
16 A
36 A
21 A
3 A / 10 V --150 A / 16 V
4 A / 20 V --150 A / 26 V
150 A / 16 V
120 A / 15 V
95 A / 14 V
150 A / 26 V
140 A / 25.
V
5
110 A / 24.
V
5
90 A / 23.
V
5
0.62
77 %
71 -- 78 V
20 V
--10˚C -- + 40˚C
<70 db
394 x 267 x 274 mm
CaddyTig 10 kg
CaddyArc 9 kg
IP 23C
- - 5 - -
OrigoTig 150
230 V ±10% 1∼ 50/60 Hz
16 A
36 A
21 A
3 A / 10 V --150 A / 16 V
4 A / 20 V --150 A / 26 V
150 A / 16 V
120 A / 15 V
95 A / 14 V
150 A / 26 V
140 A / 25.
V
5
110 A / 24.
V
5
90 A / 23.
V
5
0.62
77 %
71 -- 78 V
--
--10 ˚C till + 40˚C
<70 db
380 x 180 x 300 mm
9 kg
IP 23C
S0740 800 161/E061205/P66

Hide quick links:

Advertisement

Table of Contents
loading