Version 2 Of Circuit Board 20Ap1 - ESAB Caddyt Arc 150i Service Manual

Hide thumbs Also See for Caddyt Arc 150i:
Table of Contents

Advertisement

Version 2 of circuit board 20AP1

Execute
Show
Keep depressed more
than 5 seconds to activate
the service functions
CaddyTig, control keys for the service functions
Quit
Execute
Keep depressed more
than 5 seconds to activate
the service functions
Show
OrigoTig, control keys for the service functions
Function
no.
1
Show software version
Press
to read the actual software version.
Execute
2
Reset
Press
to display the actual reset function.
Show
Select reset function by turning the selection knob.
Press
and then
Show
Press
to leave this function.
Quit
If you have performed general reset:
S
Turn Off and On the machine.
The display shows E19 U0, reset this by pushing any button.
5
Activate HF generator
Press
, the display shows "1", the HF generator is active.
Execute
Press
to deactivate the HF generator, the display shows "0".
Execute
Press
to leave this function.
Quit
6
Activate gas valve
Press
, the display shows "1", the gas valve is active.
Execute
Press
to deactivate the gas valve, the display shows "0".
Execute
Press
to leave this function.
Quit
7
Activate the thermal overload indication LED
Press
to turn on the LED
Execute
Press
to turn off the LED.
Execute
Press
to leave this function.
Quit
ct27f1
Quit
Select function
Set value
Select function
Set value
to reset the selected function.
Execute
Execute
Show
Keep depressed more
than 5 seconds to activate
the service functions
CaddyArc, control keys for the service functions
- - 41 - -
Quit
Select function
Set value
Available reset functions:
1 = General reset.
2 = Error log reset.
3 = Default parameter reset.
4 = Memory reset.
S0740 800 161/E061205/P66