Ap1:10 Machine Type Configuration - ESAB Caddyt Arc 150i Service Manual

Hide thumbs Also See for Caddyt Arc 150i:
Table of Contents

Advertisement

The hot start current, phase 2 above, is engaged for 240 milliseconds. It is set
in per cent of the set current, but does never exceed the peak current.

20AP1:10 Machine type configuration

This circuit board is used for different machines, therefore it must be
configured.
Version 2 of circuit board 20AP1: the board is configured by the software,
see service function 23 and 24 on page 43.
Version 1 of circuit board 20AP1: the board is configured by jumpers on a
terminal, follow the instruction below.
The jumpers on terminal JP must be set up for the machine type in which the
board is used. See the table above.
20AP1:11 Power- -up starting sequence
The starting sequence on power--up is only
displayed by version 2 of circuit board
20AP1.
The circuit board displays the starting
sequence from power--up.
LED1 lights red. Then LED1, LED2 and
LED3 lights green.
When the board has been initiated, and the
power source is in the application program,
LED1 flashes continously with a green light.
ct27d_20
OrigoTig 150
CaddyTig 150
CaddyArc 150
OrigoTig 200
CaddyTig 200
LED1
LEDs on circuit board 20AP1
- - 33 - -
1
3
5
7
9
x
x
x
x
--
--
x
x
x
--
--
--
x
x
--
x
x
x
--
--
--
x
x
--
--
LED2
LED3
S0740 800 161/E061205/P66

Hide quick links:

Advertisement

Table of Contents
loading