ESAB Caddyt Arc 150i Service Manual page 40

Hide thumbs Also See for Caddyt Arc 150i:
Table of Contents

Advertisement

Version 1 of circuit board 20AP1
25 Show - -15 V voltage
Press
to read the actual voltage. The display must show 98 to 120,
Execute
which corresponds to --13.0 to --16.0 V.
Press
for a new reading.
Execute
Press
to leave this function.
Quit
26 Activate max current reference
Press
to display the maximum current reference.
Execute
Press
to activate the current reference.
Execute
Press
twice to deactivate the current reference, and to leave the service functions.
Quit
30 LED test
Press
to run a test of the control panel LEDs.
Execute
31 Display test
Press
to run a test of the display segments.
Execute
32 Program version
Press
to read the actual software version.
Execute
Press
to leave this function.
Quit
33 Machine type
Press
to read the actual machine type, set by the strapping on circuit board 20AP1.
Execute
Quit
Execute
Keep depressed more
than 5 seconds to activate
the service functions
CaddyTig, control keys for the service functions
Quit
Execute
Keep depressed more
than 5 seconds to activate
the service functions
OrigoTig, control keys for the service functions
ct27f1
Select function
Set value
CaddyArc, control keys for the service functions
Select function
Set value
- - 40 - -
Execute
Keep depressed more
than 5 seconds to activate
the service functions
S0740 800 161/E061205/P66
Quit
Select function
Set value

Hide quick links: