INSTRUCTIONS

This chapter is an extract from the instructions for the CaddyArc 150, CaddyTig 150 and
OrigoTig 150.
SAFETY
WARNING!
Read and understand the instruction manual before installing
or operating.
INSTALLATION
The installation must be executed by a professional.
Placing
Place the power source so that its cooling air inlets and outlets are not obstructed.
Rating plate
The rating plate is located on the underside of the power source.
Mains power supply
Make sure that the welding power source is connected to the correct supply voltage and
that it is protected by the correct fuse rating. The standards for the country in question must
be complied with as regards the mains cable area. A protective earth connection must be
made in accordance with regulations.
Recommended fuse sizes and minimum cable areas
Mains voltage
Mains frequency
Fuse (delayed- -action)
100A 20% duty cycle
120A 35% duty cycle
150A 35% duty cycle
Mains cable, area
Welding cable, area
*) Note:
The installed mains cable plug is approved for maximum 16 A.
North American version: the mains cable plug is approved for maximun 18 A.
The cable area and fuse rating above comply with Swedish regulations. Use the welding power source
in accordance with the relevant national regulations.
ct27ie1
CaddyArc 150, CaddyTig 150, OrigoTig 150
230 V ¦10 %, 1--phase
50--60 Hz
10 A
16 A
20 A*)
2
3 x 2.5 mm
2
16 mm
- - 52 - -
S0740 800 161/E061205/P66