MMA WELDING

The CaddyTig 150 gives direct current, and you can weld most metals to alloy and
non--alloy steel, stainless steel and cast iron. The CaddyTig 150 allows you to weld most
coated electrodes from ∅ 1.6 to ∅ 3.25.
Settings
Function
Current
Hot start *
Arc force *
Drop welding *
ArcPlust *
*) These functions are hidden functions, see the description below.
Hidden MMA functions
The setting options for hot start, arc force, drop welding and ArcPlus are obtained by
pressing the arrow buttons,
The display then shows a letter and a number.
Function
C = arc force
d = drop welding
F = welding control ArcPlust
H = hot start time
Select function by using the arrow buttons to step up and down.
Select setting with the setting knob.
Leave hidden functions by pressing the arrow buttons simultaneously for 1 second.
Hot start
Hot start increases the weld current for an adjustable time at the start of welding, thus
reducing the risk of poor fusion at the beginning of the joint.
Arc force
The Arc Force setting alters the machine's dynamics. A softer/harder arc can be obtained.
The arc force is important in determining how the current changes in response to a change
in the arc length. A lower value gives a calmer arc with less spatter.
Drop welding
Drop welding can be used when welding with stainless electrodes. This technique involves
alternately striking and extinguishing the arc in order to achieve better control of the supply
of heat. The electrode needs only to be raised slightly to extinguish the arc.
Welding current control - - ArcPlust
The CaddyTig 150 is supplied with ArcPlust, a type of control that produces an intensive,
concentrated and calm arc. It recovers quickly after a drop short--circuit, which reduces the
risk of the electrode becoming stuck. In most welding applications the best result is
achieved if ArcPlustis On.
ct27ie1
Setting range
4 -- 150 A
0 -- 99
0 -- 99
On / Off
On / Off
and
, simultaneously for at least 1 second.
Settings
0 -- 99
0 = Off; 1 = On
1 = Off; 0 = On
0 -- 99
In steps of
2 A
1
1
--
--
Default setting
5
0
0
0
- - 60 - -
CaddyTig 150
Default value
100 A
0
5
Off
On
S0740 800 161/E061205/P66