ÎÑÒÎÐÎÆÍÎ!   ÄÓÃÎ Àß Ñ ÀÐÊÀ È ÐÅÇÊÀ ÎÏÀÑÍÛ ÊÀÊ ÄËß ÈÑÏÎËÍÈÒÅËß ÐÀÁÎÒ, ÒÀÊ È ÄËß Â Â ÏÎÑÒÎÐÎÍÍÈÕ ËÈÖ. ÒÐÅÁÓÉÒÅ ÑÎÁËÞÄÅÍÈÅ ÑÅÕ ÏÐÀ ÈË ÁÅÇÎÏÀÑÍÎÑÒÈ,    ÄÅÉÑÒ ÓÞÙÈÕ ÍÀ ÎÁÚÅÊÒÅ, ÊÎÒÎÐÛÅ ÄÎËÆÍÛ Ó×ÈÒÛ ÀÒÜ Ñ ÅÄÅÍÈß ÎÁ ÎÏÀÑÍÎÑÒßÕ, Â...
DIRECTIVE DECLARATION OF CONFORMITY ESAB AB, Welding Equipment, SE--695 81 Laxå, Sweden, gives its unreserved guarantee that weld- ing power source Tig 2200i AC/DC from serial number 718 (2007 w.18) are constructed and tested in compliance with the standard EN 60974--1 /--3 and EN 60974--10 in accordance with the requirements of directive (2006/95EC) and (2004/108/EEC).
WARNING! Read and understand the instruction manual before installing or operating. ESAB can provide you with all necessary welding protection and accessories. INTRODUCTION The Tig 2200i AC/DC is a TIG welding power source, which can also be used for MMA welding. It can be used with alternating current (AC) or direct current (DC).
Control panels TA33 AC/DC S TA34 AC/DC See the separate instruction manual for a detailed description of the control panels. TECHNICAL DATA Tig 2200i AC/DC Mains voltage 230V, ±10%, 1∼ 50 Hz Primary current 27.4 A 25.0 A Open- -circuit voltage 40 W Setting range TIG AC* / DC...
Duty cycle The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer- tain load without overloading. The duty cycle is valid for 40˚C ambient temperature. Enclosure class The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid objects or water.
Recommended fuse sizes and minimum cable area Tig 2200i AC/DC Mains voltage 230 V ¦10 %,1μ 230 V ¦10 %,1μ Mains frequency 50 Hz 50 Hz Mains cable area mm 3G2,5 3G2,5 Phase current I RMS 14 A 15.3 A Fuse anti--surge 16 A...
Key to symbols Return clamp Connection to cooling unit Only those persons who have appropriate electrical knowledge (authorized personnel) may remove the safety plates to connect or carry out service, maintenance or repair work on welding equipment. See installation instructions on page 23. Turning on the power source Turn on the mains power by turning the mains switch to the ”1”...
MAINTENANCE Regular maintenance is important for safe, reliable operation. Only those persons who have appropriate electrical knowledge (authorized personnel) may remove the safety plates to connect or carry out service, maintenance or repair work on welding equipment. Note! All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work in the product during the guarantee period in order to rectify any faults.
0460 226 074 Instruction manual Control panel, Caddyt TA33 AC/DC 0460 227 074 Instruction manual Control panel, Caddyt TA34 AC/DC Instruction manuals and the spare parts list are available on the Internet at www.esab.com - - 26 - - Edition 070424 bt33o...
Tig 2200i AC/DC Accessories Äîïîëíèòåëüíûå ïðèíàäëåæíîñòè Remote control adapter RA12 12 pole ..0459 491 910 For analogue remote controls to CAN based equipment. Remote control unit MTA1 CAN ..0459 491 880 MIG/MAG: wire feed speed and voltage MMA: current and arc force...
Need help?
Do you have a question about the Caddy Tig 2200i AC/DC and is the answer not in the manual?
Questions and answers