JTS UF-10R Product Manual page 20

Professional wideband (60~75mhz) true diversity system
Hide thumbs Also See for UF-10R:
Table of Contents

Advertisement

6-3 System operation setup for Body-Pack transmitter // UF-10TB
6-3-1 Turn power on for UF-10TB Body-Pack transmitter (Fig. 5)
(1) Turn on power: press power key once
(2) Shut down power: press and hold power key for 2 seconds.
(3) Mute setup : When microphone is in use and mute setup is needed:
Set mute: short press power key once; indicator lamp flashes in red.
Cancel mute: short press power key again to cancel mute.
(4) Leave the setting window: press the power key once the LCD display will return to the
main window.
6-3-2 Menu function setup :
Press and hold SET key for 2 seconds; enter into function setup menu;
(1) Press
,
keys to select desired item; press SET key to enter into menu.
(2) After entering into menu, press
SET key to save setting.
1. Freq.: set frequency
(1) Press
,
keys to Freq. ; press SET key to enter into frequency adjustment
screen.
(2) After going to frequency adjustment screen, first adjust left 3 digits ;
Press
,
keys with "+/-" 1 MHz as unit change; after adjustment press
SET key to adjust right 3 digits
(3) Adjust right 3 digits : press
,
after adjustment press SET key to save setting.
35
Professional Wideband (60~75MHz) True Diversity System
Fig. 5
UHF PLL Transmitter
,
keys to select desired value : press
keys with "+/-" 0.025 MHz as unit change;
2. Group: set group and channel
(1) Press
(2) After entering into the screen, press
press SET key to switch to Channel setup.
(3) Press
3. Sensit: microphone sensitivity setup
(1) Press
screen.
(2) Press
to save setting ; adjustable range from -18dB to +12dB.
4. Attenuate : Microphone Attenuate
Freq.
(1) Press
Group
Sensit.
Attenuate
(2) Press
Frequency
ON: -20dB attenuation
G: 1
C:1
625
.500
OFF: No attenuation
Frequency
G: 1
C:1
625 .
500
,
keys to Group; press SET key to enter into "Group" setup screen.
,
keys to select the desired group ;
,
keys to select the desired channel; press SET key to save setting.
,
keys to Sensit; press SET to enter into "Sensit" sensitivity setup
,
keys to adjust sensitivity with 3dB as unit change ; press SET key
,
key to Attenuate. Press SET to enter "Attenuate"setup screen.
,
key to select ON or OFF
Group
Sensit.
Attenuate
Device ID
Group/Chan
G:
1
C: 1
625 . 500
Group/Chan
G: 1
C:
1
625 . 500
Sensit.
Attenuate
Device ID
Remoset
Sensitivity
12 dB
Attenuate
Device ID
Remoset
RF Power
Attenuate
ON
OFF
36

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UF-10R and is the answer not in the manual?

This manual is also suitable for:

Uf-10tbUf-10th

Table of Contents