8.3
Other BIOS Error Messages
Table 8.3
Other BIOS Error Messages
Message
Following SCSI disk
not found and no
empty slot available
for mapping it
Following SCSI IDs
have the same data y,
z
Channel x: a, b, c
Unresolved
configuration
mismatch between
disks and NVRAM on
the adapter
8.4
Other Potential Problems
Table 8.4
Other Potential Problems
Topic
DOS ASPI
Table 8.3
describes other BIOS error messages, their meaning, and
suggested solutions.
Problem
The physical disk roaming
feature did not find the
physical disk with the
displayed SCSI ID. No slot is
available to map the physical
drive. MegaRAID cannot
resolve the physical drives
into the current configuration.
The physical drive roaming
feature found the same data
on two or more physical drive
on channel x with SCSI IDs a,
b, and c. MegaRAID cannot
determine the drive that has
the duplicate information.
The configuration stored in the
MegaRAID NVRAM does not
match the configuration stored
on the drives.
Table 8.4
describes other potential problems.
Information
MEGASPI.SYS, the MegaRAID DOS ASPI manager, uses 6 Kbytes of system
memory once it is loaded.
Other BIOS Error Messages
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Suggested Solution
Reconfigure the array.
Remove the drive or drives that should not
be used.
1. Press a key to run MegaRAID Manager.
2. Select View/Add Configuration from the
Configure menu.
3. Use View/Add Configuration to examine
both the configuration in NVRAM and the
configuration stored on the disk drives.
4. Resolve the problem by selecting one of
the configurations.
8-5