LSI MegaRAID SCSI 320-2 RAID Controller Series 518 Hardware Manual page 126

Lsi logic megaraid scsi 320-2 raid controller user's guide
Table of Contents

Advertisement

Table 8.2
BIOS Boot Error Messages (Cont.)
Message
X Logical Drives
Degraded
1 Logical Drive
Degraded
Insufficient memory to
run BIOS. Press any key
to continue...
Insufficient Memory
The following SCSI IDs
are not responding:
Channel x:a.b.c
8-4
Problem
x number of logical
drives signed on in a
degraded state.
A logical drive signed on
in a degraded state.
Not enough MegaRAID
memory to run
MegaRAID BIOS.
Not enough memory on
the MegaRAID adapter
to support the current
configuration.
The physical drives with
SCSI IDs a, b, and c are
not responding on SCSI
channel x.
Troubleshooting
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Suggested Solution
Make sure all physical drives are properly
connected and are powered on.
Run MegaRAID Manager to find if any physical
drives are not responding. Reconnect, replace,
or rebuild any drive that is not responding.
Make sure all physical drives are properly
connected and are powered on.
Run MegaRAID Manager to find out if any
physical drives are not responding. Reconnect,
replace, or rebuild any drive that is not
responding.
Make sure MegaRAID memory has been
properly installed.
Make sure MegaRAID memory has been
properly installed.
Make sure the physical drives are properly
connected and are powered on.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Megaraid scsi 320-2

Table of Contents