6.2.3.2
Recommended Memory Vendors
6.2.4

Step 4: Check Jumper Settings

6. You can now add or remove DRAM modules from the MegaRAID
controller, as described above.
7. Reattach the battery pack harness to J10 on the MegaRAID
controller.
8. Reinstall the MegaRAID controller in the computer. Follow the
instructions in this chapter.
9. Replace the computer cover and turn the computer power on.
Call LSI Logic Technical Support at 678-728-1250 for a current list of
recommended memory vendors.
Make sure the jumper settings on the MegaRAID SCSI 320-2 card are
correct. The jumpers are set at the factory and you probably do not need
to change them.
Table 6.2
Table 6.2
Jumpers for the MegaRAID SCSI 320-2
Item
Description
J2
SCSI activity LED connector
J3
Write pending indicator
J4
SCSI Termination Enable Channel 0
J5
SCSI Termination Enable Channel 1
J10
Battery connector
J16
BIOS Enable
J17
Termination Power Channel 0
J18
Termination Power Channel 1
Figure 6.2
shows the location of these items on the MegaRAID SCSI
320-2 controller.
Installation Steps
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
lists the jumpers that you should check.
Type
4-pin header
2-pin header
3-pin header
3-pin header
3-pin header
2-pin header
2-pin header
2-pin header