Guidelines for Calibrating the Touch Screen

Calibration Procedure

The following guidelines should be observed for calibrating the touch 
screen. 
Calibration should be done at time of installation 
Recalibrate the touch screen when the system is installed at its final 
location. 
Recalibrate whenever the terminal is moved to a new location. 
Recalibrate the touch screen anytime the system has been 
disassembled for servicing. 
Only use the Microcal (DOS) program, the Touchware Control 
Panel (Windows), or Touchware icon on the Desktop (XPe)  to 
calibrate the touch screen. 
Microcal:  
a. Set the video resolution. Go to the 
x 600 256 colors
b. Go to the 
Tools
Touchware Control Panel: 
a. Go to the 
Calibrate
The calibration program looks at where your finger is when you lift it 
off the screen, not where you touch it. Therefore, calibrate the screen as 
follows: 
1. Touch the screen near the calibration target. 
2. Keep your finger on the screen and slide it to the center of the 
target. 
 menu, select 
Calibrate
 tab and press 
Calibrate