Guidelines for Calibrating the Touch Screen
Calibration Procedure
The following guidelines should be observed for calibrating the touch
screen.
•
Calibration should be done at time of installation
•
Recalibrate the touch screen when the system is installed at its final
location.
•
Recalibrate whenever the terminal is moved to a new location.
•
Recalibrate the touch screen anytime the system has been
disassembled for servicing.
•
Only use the Microcal (DOS) program, the Touchware Control
Panel (Windows), or Touchware icon on the Desktop (XPe) to
calibrate the touch screen.
Microcal:
a. Set the video resolution. Go to the
x 600 256 colors
b. Go to the
Tools
Touchware Control Panel:
a. Go to the
Calibrate
The calibration program looks at where your finger is when you lift it
off the screen, not where you touch it. Therefore, calibrate the screen as
follows:
1. Touch the screen near the calibration target.
2. Keep your finger on the screen and slide it to the center of the
target.
.
menu, select
Calibrate
tab and press
Calibrate
Chapter 2: Hardware Installation 2-37
menu,
Tools
Video
.
.
. Select
800