Chapter 6: NCR 7454 4x20 Customer Display

Diagnostics

Power‐Up Diagnostics occur soon after the hardware reset circuitry is 
released, or when a Reset Display command is received from the host 
software. When the hardware is powered down, all registers and 
memory are lost. The display is not capable of any kind of power 
recovery back to a previous state. As a part of the Power‐Up 
Diagnostics, the working registers and variables are initialized (set to 
zero). 
The self‐diagnostics include: 
1. Micro‐controller Test 
The Busy line is set active at the beginning of the test. The first test 
is Exclusive‐ORing all internal program memory locations and the 
result of the test is zero. Any unused bytes in the summed page are 
always programmed with null values so that they do not have an 
impact on the execution of the test. An internal RAM test writes a 
varying numerical value to each RAM location. The pattern must 
show that all RAM locations can be uniquely addressed. All RAM 
will be written. After the write phase is complete, a read phase 
begins to ensure the writes held. If an error is discovered, testing 
halts and the firmware begins executing a forever do nothing loop. 
2. Display Test 
The display will run an extra test that turns on all pixels on the 
display (character cells) for about two seconds and then displays 
the part number and the firmware version "008‐0221552, V1.00.01" 
for another two seconds. This permits a user to examine the display 
for any pixel failure. The unit does not have the capability to 
determine if the Display Test passed. Once diagnostic testing is 
completed, the line states will be returned to normal and the 
firmware branches to its idle routine. 
Note: When the I/F receives a Reset command, only Step 1 is 
executed. The Display Test is not executed.  