Warning - Nikon Eclipse LV100DA-U Instructions Manual

Universal design microscope udn
Table of Contents

Advertisement

WARNING

1. Intended product use
The product should only be used for microscopic observation. Do not use this microscope
for other purpose. In addition, do not try to put a large specimen on the stage if the specimen
is larger than the stage.
2. Do not disassemble
Disassembling the microscope or the microscope system may result in electric shock or
malfunctions. Damage or injury that may occur due to mishandling is unwarranted. Never
attempt to disassemble any part other than the parts described in this manual. If you
experience problems with the microscope or the microscope system, contact your nearest
Nikon representative.
3. Read the instructions carefully
To ensure safety, carefully read this manual and the manuals for other equipment used with
this microscope. In particular, observe all warnings and cautions given at the beginning of
each manual.
To use an external light source
When an external light source, such as a mercury lamp or a xenon lamp, is used, you must
take great care of the lamp. Read the instruction manual for the light source and follow the
instructions and cautions for it.
4. Ratings of the power supply
The power supply circuit in this product is designed for AC power of 100 to 240 VAC and
50/60 Hz. Before connecting the power cord, check that the power supply to be used
conforms to the voltage and frequency described above. Use of a non-conforming power
line may result in equipment malfunction, failure, or fire.
5. Power cord
Be sure to use the specified power cord for the product. Using a wrong power cord may
result in malfunctions or fire. The product is classified as subject to Class I protection
against electrical shock. Make sure it is connected to an appropriate ground terminal
(protective earth terminal). To prevent electrical shock, always turn off the power switch
(press it to the " " position) for the microscope before attaching or detaching the power
cord. For specifications of the power cord, refer to "VII. Specifications."
6. Specified light source
Use this product with a specified light source. The specified light source devices are as
follows:
• Illuminator (for the epi-illumination):
Nikon LV-UEPI2A Motorized Universal Epi Illuminator 2A (model name: LV-UEPI2A)
• Lamp house (for the epi-illumination and the dia-illumination)
Nikon LV-LH50PC Precentered Lamp House 12V 50W (model name: LV-LH50PC)
• Lamp
Nikon LV-HL50W 12V 50W LONGLIFE halogen lamp (model name: LV-HL50W), or
non-Nikon 12V 50W SHORTLIFE halogen lamp (model name: OSRAM HLX 64610,
OSRAM HLX 64611, or PHILIPS 7027).
• Power supply (It is used to turn on the episcopic illumination and the diascopic
illumination simultaneously.)
Nikon TE2-PS100W Power Supply (model name: TE2-PS100W)
This power supply is connected to the lamp house for the episcopic illumination to turn on
the episcopic illumination and the diascopic illumination simultaneously.
If you wish to buy these lamps, please contact your nearest Nikon representative.