Fan Motor (Dc Motor) Or Related Abnormality - Daikin FTX50GV1B Service Manual

Hide thumbs Also See for FTX50GV1B:
Table of Contents

Advertisement

Troubleshooting
4.4

Fan Motor (DC Motor) or Related Abnormality

A6
Error Code
Method of Error
The rotation speed detected by the Hall IC during fan motor operation is used to determine
abnormal fan motor operation.
Detection
Error Decision
The detected rotation speed does not reach the demanded rotation speed of the target tap, and
is less than 50% of the maximum fan motor rotation speed.
Conditions
Supposed
Causes
59
Remarkable decrease in power supply voltage
Layer short inside the fan motor winding
Breaking of wire inside the fan motor
Breaking of the fan motor lead wires
Defective capacitor of the fan motor
Defective indoor unit PCB
SiBE041029EC
Service Diagnosis