Disconnect each power cord from the server.
b.
For tower models, do the following:
4.
Place the server on a flat, level surface with the access panel facing up.
a.
Remove the access panel
b.
For rack models, do the following:
5.
Extend the server from the rack (on page 28).
a.
Remove the access panel
b.
Release thumbscrews and remove the rack bezel.
c.
Remove the air baffle
6.
Remove the fan cage.
7.
Disconnect and remove the optical drive power and data cables.
8.
Remove the optical drive.
9.
To replace the component, reverse the removal procedure.
Front I/O assembly
To remove the component:
Do one of the following:
1.
For tower models, open and remove the bezel
o
For rack models, if installed, remove the security bezel (on page 27).
o
Power down the server (on page 26).
2.
Remove all power:
3.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
For tower models, do the following:
4.
Place the server on a flat, level surface with the access panel facing up.
a.
("Access
panel" on page 29).
("Access
panel" on page 29).
("Air
baffle" on page 30).
("Remove the tower
bezel" on page 27).
Removal and replacement procedures 39