Install the heatsink, and then close the heatsink retaining levers.
6.
Install the air baffle.
7.
Install the access panel.
8.
Do one of the following:
9.
For tower models, return the server to an upright position.
o
For rack models, slide the server back into the rack.
o
Connect each power cord to the server.
10.
Connect each power cord to the power source.
11.
Press the Power On/Standby button.
12.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
Do one of the following:
13.
For tower models, install the bezel.
o
For rack models, if removed, install the security bezel.
o

DIMMs

CAUTION:
baffle, drive blanks, and access panel must be installed when the server is powered up.
To remove the component:
Do one of the following:
1.
For tower models, open and remove the bezel
o
For rack models, if installed, remove the security bezel (on page 27).
o
Power down the server (on page 26).
2.
Remove all power:
3.
Disconnect each power cord from the power source.
a.
To avoid damage to the hard drives, memory, and other system components, the air
("Remove the tower
bezel" on page 27).
Removal and replacement procedures 63