Specifications

Environmental specifications

Specification
Temperature range*
Operating
Nonoperating
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.

Server specifications

Specification
Dimensions
Rack model
Height
Depth
Width
Tower model
Height
Depth
Width
Weight
Rack model
Maximum
Minimum
Tower model
Maximum
Minimum

Power supply specifications

Depending on installed options, the server is configured with one of the following power supplies:
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
10% to 90%
5% to 95%
Value
21.8 cm (8.58 in)
73.22 cm (28.83 in)
48.26 cm (19.00 in)
46.2 cm (18.19 in)
74.00 cm (29.13 in)
21.8 cm (8.58 in)
50.06 kg (110.36 lbs)
27.63 kg (60.91 lbs)
52.09 kg (144.84 lbs)
31.09 kg (70.33 lbs)
Specifications 93