Radyne DMD20 Installation And Operation Manual page 178

Universal satellite modem
Table of Contents

Advertisement

DMD20 Universal Satellite Modem
<1>
Insert Status Fault
<1>
Common Alarm1
<1>
Common Alarm2
Opcode: <240Dh>
<2>
Raw BER Mantissa
<2>
Corrected BER
Mantissa
<2>
EbNo
<1>
Raw BER Exponent
<1>
Corrected BER
Exponent
<1>
BER/EbNo Status
<1>
Input Level
Opcode: <240Eh>
<1>
Hour
<1>
Minute
<1>
Second
TM105 – Rev. 1.1
Bit 0 = Frame lock fault. 1 = Fail
Bit 1 = Multiframe lock fault. Valid in E1 PCM-30 and PCM -
30C. 1 = Fail
Bit 2 = CRC lock fault. Valid in T1ESF, and E1 CRC enabled.
1 = Fail
Bit 3 = T1 yellow alarm received. 1 = Received
Bit 4 = E1 FAS alarm received. 1 = Received
Bit 5 = E1 MFAS alarm received. Not valid in FAS mode. 1 =
Received
Bit 6 = E1 CRC alarm received. 1 = Received
Bit 7 = CRC calculation error. 1 = Fail
TBD
TBD
Query a modem's Eb/No, BER, and Level
Query Response
Bytes 1 - 2 = Binary value Raw BER
Bytes 1 - 2 = Binary value corrected BER
Binary value, 1 decimal point implied
Byte 3 = Binary value exponent
Byte 3 = Binary value exponent
Bit0 = Raw BER and corrected BER status. 1 = Valid
Bit1 = Test 2047 BER status. 1 = Valid
Bits 2 – 3 = EbNo status, 0 = EbNo is invalid
1 = EbNo is valid, 2 = EbNo is smaller than indicated
value, 3 = EbNo is greater than indicated value
Bit 4 = BER Counter Overflow.
1 = Overflow Condition
Bit 5 = Test 2047 BER Counter Overflow
1 = Overfl ow Condition
Bits 6 – 7 = Reserved