Radyne DMD20 Installation And Operation Manual page 158

Universal satellite modem
Table of Contents

Advertisement

DMD20 Universal Satellite Modem
Opcode: <2618h>
<1>
Baseband Loopback
Opcode: <2619h>
<1>
Mode
Opcode: <261Ah>
<4>
External EXC Clock
Opcode: <261Bh>
<4>
External Ref. Freq.
Opcode: <261Dh>
<1>
T1D4 Yellow Alarm
sel.
Opcode: <261Eh>
<1>
Tx Interface Type
Opcode: <261Fh>
<11>
Circuit ID
Opcode: <2622h>
<1>
Summary Alarm
Opcode: <2623h>
<1>
Data Invert
Opcode: <2625h>
Opcode: <2629h>
<1>
AUPC Local Enable
Opcode: <262Ah>
<1>
AUPC Remote
Enable
Opcode: <262Bh>
<1>
AUPC Local CL
Action
TM105 – Rev. 1.1
Command a modulator's baseband loopback
0 = Disable, 1 = Enable
Command a modulator's mode
0 = Closed Net. 1 = IDR, 2 = IBS, 3 = D&I
Command a modem's external EXC clock
Binary value, 1 BPS steps
Command a modem's external reference frequency
Binary value, 1 BPS steps
Command a modulator's T1D4 Yellow alarm selection
0 = Bit2 eq. 0 for all channels. 1 = Frame 12 s-bits eq. 1
Command a modulator's interface type
0 = G703-B-T1_AMI
1 = G703-B-T1_B8ZS
2 = G703-B-E1
3 = G703-B-T2
4 = G703-U-E1
5 = G703-U-T2
6 = G703-U-E2
7 = RS-422
8 = V.35
9 = RS-232
Command a modulator's circuit ID
11 ASCII characters
Command Force Mod Summary Alarms
0 = Do not force. 1 = Force
Command Modulator Data Invert
0 = None, 1 = Terrestrial, 2 = Baseband, 3 = Terrestrial and
Baseband
Clear a modulator's Latched Alarm 1 (No Data)
Command AUPC Local Enable
0 = Off, 1 = On
Command AUPC Remote Enable
0 = Off, 1 = On
Command AUPC Local CL Action
0 = Hold, 1 = Nominal, 2 = Maximum