Appendix B
Opcode: <260Eh>
<1>
Drop Mode
Opcode: <260Fh>
<2>
Transmit Power Level
Opcode: <2610h>
<1>
ReedSolomon
Opcode: <2611h>
<1>
Spectrum
Opcode: <2612h>
<1>
Operating Mode
Opcode: <2613h>
<1>
Scrambler Control
Opcode: <2614h>
<1>
Scrambler Type
Opcode: <2615h>
<1>
Framing
Opcode: <2616h>
<1>
External Ref. Source
Opcode: <2617h>
<1>
Terrestrial Loopback
B-18
Command a modulator's drop mode
0 = Disabled
1 = T1 -D4
2 = T1-ESF
3 = PCM-30
4 = PCM-30C
5 = PCM-31
6 = PCM-31C
7 = SLC-96
8 = T1 D4 S
9 = T1 ESF S
Command a modulator's output level
Signed value. +50 to -300 (+)5.0 to -30.0 dBm). The range is
+5.0 to –20.0 dBm for the 70/140 MHz type modems and –5.0
to –30.0 dBm for the L-Band type modems. Implied decimal
point.
Command a modulator's ReedSolomon
0 = Disable, 1 = Enable
Note: This command also turns the Carrier off.
Command a modulator's spectrum
0 = Normal, 1 = Inverted
Command a modulator's operating mode
0 = Normal, 1 = 2047 test
Command a modulator's scrambler control
0 = Disable, 1 = Enable
Command a modulator's scrambler type
0 = None
1 = IBS Scrambler
2 = V.35IESS
3 = V.35CCITT
4 = V.35EFDATA
5 = V.35FAIRCHILD
6 = OM-73
7 = R-S Scrambler
8 = V.35EF R-S Scrambler
9 = TPC Scrambler
Command a modulator's framing
0 = No framing, 1 = 96K, 2 = 1/15, 3 = EF AUPC 1/15
Command a modem's external reference source
0 = Internal, 1 = External, 2 = High Stability
Command a modulator's terrestrial loopback
0 = Disable, 1 = Enable