1.2.15 The dosimeter is resistant to the following external factors:
- high frequency sinusoidal vibrations (with crossover frequency from
57 to 62 Hz) in the range of 10 to 55 Hz, 0.15 mm bias for frequency lower
than the crossover frequency;
- shocks with a shock pulse duration of 5 ms, a total number of shocks
1000±10 and maximum acceleration of 100 m/s
- shocks in shipping container with an acceleration of 98 m/s
shock pulse duration of 16 ms (number of shocks - 1000±10 in each
direction), or equivalent shake tests;
- exposure in shipping container to ambient air temperature from - 25
to + 55 o C and relative humidity up to (95±3) % at + 35 o C;
- photon-ionizing radiation with exposure dose rate that corresponds to
ambient DER up to 1.0 Sv/h during 5 minutes.