Version 2.x supports three FRU Inventory Device Commands:
Get FRU Inventory Area Info
Read FRU Data
Write FRU Data
The spare SEEPROM space is allocated as follows:
Space for
VPD
FRU
Parameters
Attribute

IPMB Override/Local Status - Event Data 3 for the IPMB link

Bit(s)
Ethernet Switch Blade User's Guide
Downloaded from
www.Manualslib.com
Spare SEEPROM Space Allocation
Start address
0
0x400
0x1400
0x1800

Table C.8: SEEPROM Space

Type
7
IPMB B Override State
6:4
IPMB B Local Status
3
IPMB A Override State
2:0
IPMB A Local Status
manuals search engine
End address
Size
0x3FF
0x400 (1Kbytes)
0x13FF
0x1000 (4kbytes)
0x17FF
0x400 (1 Kbytes)
0x37FF
0x2000 (8
Kbytes)
IPMB Override Status Data
Notes
0=Override state, bus isolated; 1= Local Control state - IPM
Controller determines state of bus
0=No Failure. Bus enabled if no override in effect;
1=Unable to drive clock HI; 2=Unable to drive data HI;
3=Unable to drive clock LO; 4= Unable to drive data LO;
5= Clock low time out; 6=under test; 7=Undiagnosed
communications failure
0=Override state, bus isolated; 1= Local Control state - IPM
Controller determines state of bus
0=No Failure. Bus enabled if no override in effect;
1=Unable to drive clock HI; 2=Unable to drive data HI;
3=Unable to drive clock LO; 4= Unable to drive data LO;