5.1.4.3
DTMF Signal
This test mode is used to check the DTMF (Dual Tone Multi Frequency) signal output.
The DTMF signal can be generated using the following procedure.
Step
1
Standby
2
Press "FUNCTION" and then "7".
3
Press "MONITOR" four times, then press "*".
4
Press "4".
5
Press "3" and "START".
6a
Press "START" for DTMF Single Tone Generation.
7a
Enter the signal number (1-8) to select the DTMF
signal.
6b
Press "2" and "START" for Dual Tone Generation.
7b
Enter the signal number (0-#) to select the DTMF Dual
tone.
8
Press "CLEAR" to end the signal generation. To select
another signal, repeat step 7a or 7b.
9
Press "STOP" twice to return to standby.
DTMF Single Tone Table
Number
1
2
3
4
5
6
7
8
Operation or Unit Condition
DTMF Signal Tones
697 Hz
770 Hz
852 Hz
941 Hz
1209 Hz
1336 Hz
1477 Hz
1633 Hz
DTMF Dual Tone Table
Number
0
1
2
3
4
5
6
7
8
9
*
#
198
LCD Display
FEB-12-2002
15:00
00%
SET MODE
(1-6)
ENTER NO. OR
SERVICE MODE
ENTER NO. OR
MODEM TEST (1-5)
1:SIGNAL TEST
DTMF TEST (1-2)
1.SINGLE
SINGLE TONE
ENTER (1-8)
SINGLE TONE
697Hz
DUAL TONE
ENTER (0-#)
DUAL TONE
(0)
SINGLE TONE
ENTER (1-8)
FEB-12-2002
15:00
00%
DTMF Signal Tones
941 Hz + 1336 Hz
697 Hz + 1209 Hz
697 Hz + 1336 Hz
697 Hz + 1477 Hz
770 Hz + 1209 Hz
770 Hz + 1336 Hz
770 Hz + 1477 Hz
852 Hz + 1209 Hz
852 Hz + 1336 Hz
852 Hz + 1477 Hz
941 Hz + 1209 Hz
941 Hz + 1477 Hz