Parameter
No.
(see Note 3)
068 NYSE FAX FOR-
WARD
069 NYSE LOCAL PRINT 1 = Inc
070 LINE ERROR
071 TOTAL ERROR
072 CONTINUOUS
ERROR
073 ERROR DETECT
074 RTN RECEIVE
075 MH/MR/MMR/JBIG
076 Not used
077 RX JAM LENGTH
078
Not used
079
080 DOC TOP FEED
081 DOC END FEED
Function Parameter Table
Selections
1 = Off
2 = On
2 = On (Always)
1 = 128 lines
2 = 256 lines
3 = 512 lines
4 = 1024 lines
5 = 2048 lines
6 = Off (will not disconnect
line)
1 = 5%
2 = 10%
3 = 15%
4 = 20%
1 = Off (unlimited)
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
1 = Lines
2 = Rate
1 = Disconnect
2 = Continue
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR (MH or MR or
MMR)
4 = JBIG
1 = Off (unlimited)
2 = 2 m
3 = 8 m
-5.0 mm
~
+5.0 mm
-5.0 mm
~
+5.0 mm
177
Function
Selects whether the machine will
forward the incoming and outgoing
faxes to a specified station.
Note:
Once this parameter is activated, Fax
Forwarding via Fax Parameter 054 is
automatically disabled.
Selects the printing condition for the
incoming faxes after FAX Forwarding.
Inc.: Prints only if FAX Forwarding fails.
On: Always prints.
1.Selects the line disconnect condition
during reception. If the number of line
errors exceed this setting, the unit will
disconnect the line.
2.Selects the transmit condition of RTP/
PIP or RTN/PIN. (Available if No.73
ERROR DETECT is set to "LINES")
(See Note 1)
Selects the transmit condition of RTP/
PIP or RTN/PIN.
(Available if No.73 ERROR DETECT is
set to "RATE") (See Note 2)
Selects the continuous total error criteria
of Off/3/6 or 12 lines in Standard mode.
If continuous total error exceeds this
setting, the unit will transmit RTN/PIN.
(Available if No.73 ERROR DETECT is
set to "RATE".)
Selects the error detect condition Lines/
Rate.
Selects whether to disconnect the
phone line or continue when "RTN" is
received.
Selects the coding scheme.
Selects the maximum length of a
received document that can be printed.
Adjusts the distance between the
scanning sensor ON position and the
scanning start position.
Adjusts the distance between the
scanning sensor OFF position and the
scanning end position.