Parameter
No.
(see Note 3)
000 MON/TEL DIAL
001 ALARM STATUS
002 STOP COMM. JRNL
003 CONTINUOUS POLL 1 = Off
004 NUMERIC ID SET
005 Not Used
006 ID DISPLAY
007 JNL COLUMN
008 MONITOR
009 DC LOOP
010 TX LEVEL
011 RX LEVEL
012 DTMF LEVEL
Function Parameter Table
Selections
1 = Monitor
2 = TEL/DIAL
1 = OFF
2 = Timer (6 sec.)
3 = Constant
1 = Off
2 = On
2 = Stn (Tx only)
3 = Hub (Rx only)
1 = Off (will not accept)
2 = On (accepts)
1 = Number (Numeric ID)
2 = Chara (Character ID)
1 = Preset station name
2 = Received ID
1 = Off
2 = On
1 = Off (Normal)
2 = On (Off Hook)
00 = 0 dBm
~
15 = -15 dBm
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
00 = 0 dBm
~
15 = -15 dBm
173
Function
Selects whether the machine starts to
TX automatically during On-Hook dial-
ing.(Monitor: Start to TX after pressing
START)
(TEL/DIAL: Start to TX automatically)
Selects the No Paper or No Toner alarm
status.
OFF : Alarm is disabled.
Timer : Alarm will shut off after 6
seconds.
Constant : Alarm will not stop until
"STOP" is pressed or the error is
cleared/corrected.
Selects whether the machine prompts to
print the COMM. Journal when the
printout condition is set to INC and
STOP is pressed during
communication.
Selects whether the Continuous Polling
feature is enabled.
Stn:
Place the document(s) on the ADF then
press the Program Key [P8] to store or
add the document(s) into a polled file.
(See Note 4)
Selects whether the machine accepts
and allows to set or change the Numeric
ID.
Selects the priority of displaying the ID.
Selects the contents of the ID to display
on the Journal.
Selects whether the Monitor is ON/OFF
for monitoring fax signals.
(FOR SERVICE USE ONLY)
Selects a false Off Hook state for back
to back communication test.
Selects the TX signal output level, 0 to
-15 dBm in 1 dBm steps.
(Refer to Chapter 4.3)
Selects the receiving sensitivity of -33/
-38/-43/-48 dBm.
(Refer to Chapter 4.3)
Selects the DTMF output level, 0 to -15
dBm in 1 dBm steps.

Hide quick links: