Download Print this page

A3 Bc To Bc System Setup - ISHIDA BC-300 Service Manual

Retail scale

Advertisement

A3
BC to BC System Setup
1. Overview
The BC-3000 has limited communication capabilities as compared to the AC-3000 series. Important
system considerations are listed here.
• PLU and price changes programmed at the master scale are instantly sent to each satellite scale that
is connected and set "on-line".
• If a satellite scale is not connected or is turned off or is set "off-line" the changes cannot be registered
into its memory.
• After programming, the master scale and all of the satellite scales contain identical PLU files in their
memory.
• The memory from the master scale cannot be downloaded or retransmitted to the memory of any
satellite scale.
• A maximum of five scales (one master plus four satellites) may be connected.
2. Set Up
Three separate memory areas of each BC-3000 scale must be configured to allow master-satellite
communications.
A. Test Menu
Step C06-01: ROM Switch [Access by powering up holding 1 key, 6, ENTER]
Set the on-line flag in all scales:
address 2D = 1
[Access by entering the address and pressing the → key]
Identify satellite scales (in master scale only)
address 2E = 2
address 2F = 3 (only if a third scale is connected)
address 30 = 4 (only if a fourth scale is connected)
address 31 = 5 (only if a fifth scale is connected)
B. Programming Menu
Step P17-01: Scale Number. [Access by password 9000, MODE, 17, ENTER]
Master Scale = 1
Satellite Scale = 2 to 5
Step P19-01: On-Line Mode. [Access by password 9000, MODE, 19, ENTER]
On-Line = 1
Off-Line = 0
BC-3000 • Service Manual • Rev. 1
- BC-3000 Master/Satellite Communication -
(Firmware B-0209E & F-0194)
Appendix
Appendix - 5

Hide quick links:

Advertisement

loading