Bc-3000 - ISHIDA NOVA-II Setup Manual

Mtx series; mtb series; mte series; cws series; ncs series; qbx series; qb series; mb series; mb-re series; ib series; sb series;
Table of Contents

Advertisement

1.2

BC-3000

Follow the steps below to set up and calibrate the Ishida BC-3000 scale.
Step
1
Turn off scale.
2
Turn on scale while depressing the 1 key. Release the 1 key after two beeps.
3
Press the 1 key and push ENTER two times. xxxx=default values between 500 and 5000.
4
With no weight on the weigh platter, press the ZERO key to set the initial zero point.
5
Initial A/D value should read 2000 ± 1.
If No: Press ZERO key again;
6
Place 30 lb weight on platter.
7
Is A/D change value within 30000 ± 2?
If NO: • Press the TARE key
• Remove weight from platter and return to step 4.
8
Remove weight and weigh platter from unit to perform data registration.
9
Remove white plastic screw from unit (see illustration below).
10
Press memory switch inside unit.
11
Replace the white plastic screw and the weigh platter.
12
Press the END key twice
13
Turn scale off.
14
Turn on scale again and test the calibration by placing a known weight on the platter.
Caution
!
Action
If Yes: Proceed to step 6.
Do not use a screwdriver or
other metal tool to press the
switch in Step 10.
Figure 1-2. View of BC-3000 scale
If YES: Proceed to step 8
Memory switch
Display
C00
0
xxxx
xxxx
0
2000
0
2000
30000 32000
30000 32000
C00
0
0.00 0.00 0.00
Retail Scales
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents