2.0

Installation

WARNING
Ensure the user has read and understands the Safety section of this manual.
Always use a power supply with rated voltage. Never connect the scale power input with an AC power supply
exceeding the rated voltage. To avoid any potential electrical shock, ensure that the protective ground wire is
connected to the main grounding provision. Using the scale outside of the rated voltage may result in machine
failure or danger such as electric shock.
Prepare a dedicated power source. A power supply that generates voltage variation may cause a malfunction.
Do not stand or place anything heavy on the power cord, doing so may damage the cord.
Disconnect power supply before servicing.
Take precaution against residual electrical charge hazard. Capacitors inside the scale may still hold an electrical
charge even after power is disconnected.
Do not remove covers or enclosures.
Do not perform unspecified maintenance.
Important
Do not install the scale in the following types of places:
Subject to high temperatures or high humidity
Exposed to direct sunlight
Where water or other liquids are easily spilled on the scale
Subject to excessive vibration or unstable foundations
Exposed to direct cold air from air conditioners or refrigerators
Where the floor or foundation is unstable
Subject to a lot of dust or dirt
With large voltage fluctuations
2.1
Installation
The following is an overview of the installation procedure of the Ishida
2.1.1

Preliminary Information

1. Determine the IP address(es) to be assigned to the scale(s).
2. Determine the wireless information (optional).
2.1.2

Preliminary Setup Before Delivery

1. Remove the scale from the box.
2. Assemble the scale.
Note
For pole models, place any excess cable inside the pole—not the scale body.
3. Check the firmware version, see Section 4.5 on page 66.
4. If necessary, upgrade the firmware.
Power up the scale with USB stick installed, loaded with appropriate "soft" firmware folder.
5. Clear the scale's memory, see Section 4.6 on page 66.
6. Configure the country, see Section 3.20 on page 57.
7. Set the date and time, see Section 4.2 on page 65.
8. Program the IP Address, Subnet Mask, etc., see Section 3.2 on page 33.
9. Program the wireless settings, see Section 3.2 on page 33.
10. Verify scale communication using the Ping command and SLP-5.
11. Load labels.
12. Load backup file from USB (see Section 3.21 on page 60) or from the SLP-5 Maintenance Utility.
13. If necessary, download or create label formats using SLP-5 Maintenance Utility.
scale.