3.2 UPPER COVER REMOVAL

1. Remove the weigh platter.
1) Place the scale on a level surface.
Rotate the adjustment feet to level the scale if
necessary.
2) Unplug the power plug from its outlet.
3) Lift off the weigh platter, keeping it horizontal.
Note:
When replacing the weigh platter, align the platter pins with the rubber inserts on the platter base.
2. Remove the platter base.
Remove the four attachment screws, then lift off the
platter base.
After replacing the platter base, perform four corner adjustment (Refer to Section 5.5).
Note:
BC-3000 • Service Manual • Rev. 1