Chapter S5. Test Mode
3. Print Density (C03-03)
This item is used to adjust the thermal head print
density.
Enter the density value 1 (light) - 9 (heavy), then
press
ENTER.
Press
PRINT to print a test label to confirm
correct density.
Repeat until satisfactory.
PRINT SAMPLE
4. Label and Gap Identification
Setting (C03-04)
Set the label and gap identification value.
Input the value and press
* For an explanation of the label and gap
identification set value, refer to "Label Sensor
Adjustment" (P.5-4 Section 5.5) under Chapter
5, "Other Adjustments."
4

Sensor Check (C04)

This item is used to confirm the current label gap
sensor value.
S5 - 8
ENTER.
C03-03
Note:
1) The default value is 5.
2) A value of "0" will cause unacceptably light/
spotty printing.
C03-04
C04-00