Note
If arming to Level 3 with No
Delay, it cancels the Auto
Stay Arming feature.
Note
When a sensor is bypassed,
you are allowing that door or
window to go unprotected.
Note
Direct bypassing of sensors
can only be done at the
panel.
Note
If a key is not entered for five
seconds, the panel will exit
the bypass sensors mode.
Note
Heat, smoke, carbon mon-
oxide, and DTIM cannot be
bypassed.
Note
The panel lists bypassed
and opened sensors or
zones.
10
The system arms to Level 3 regardless of whether or not a delay door has been
opened and closed.
If feature
turned off.
Your movement inside the premises could activate a motion detector, causing an
alarm.
The dealer/installer can turn this feature on or off for you. See Table B4: System Options, on
page 19, to see if this feature is available to you.

Arming While a Door or Window is Open

It is possible to arm your system while leaving a door or window open. This is useful if, for
example, you like to sleep at night with the window open.
If the door or window has a sensor installed on it, the system must be told to ignore or bypass that
sensor when it's open. All other sensors will remain active.
There are two methods for bypassing a sensor:
Direct — After arming the system, bypass door/window sensors before you open them. You
must know the sensor name or number of the door or window you wish to bypass.
Indirect — As you are arming, bypass sensors on already-open doors and windows. This
method should not be used in UL Listed installations.
Direct Bypass
Only the primary access code can be used to bypass/unbypass sensors directly. Only sensors that
are active in the current arming level can be bypassed. Attempting to bypass a sensor that is
already bypassed, will activate or unbypass the sensor.
Refer to Table B5: Sensor Information, on page 19 to determine what the sensor number is for
the sensor you wish to bypass.
To bypass sensors directly:
1. Close all doors and windows.
2. Arm your system to the desired level.
3. Press
(
). The panel displays,
Bypass
4. Enter your primary access code. The panel displays the sensors that are active in that level
and can be bypassed in the system.
5. Use the
and
6. Press
(
) to select the sensor to be bypassed.
Select
7. The panel displays,
message will include bypassed and open sensors).
The bypassed door or window can now be opened.
Indirect Bypassing
Use this method if you are arming the system and would like to bypass doors and windows
already open.
To bypass sensors indirectly:
1. Leave open only those doors and windows that are to remain open. Close all others.
2. Arm your system to the desired level. The panel emits protest beeps and displays
and
ZONE XX OPEN
3. Press
(
) to immediately bypass or allow the delay time to expire and the sensors will
Bypass
bypass automatically.
4. The system sounds arming level beeps to indicate that the system is armed and open sensors
have been successfully bypassed.
Was the Bypass Successful?
To confirm whether or not a sensor was bypassed:
Press
(
on the panel touchpad.
Status)
To activate (unbypass) bypassed sensors (3 ways):
Press
(
) and enter primary code. Select the sensor by using the arrow buttons.
Bypass
Press
to accept the sensor to be unbypassed. The panel displays,
Enter Code TO BYPASS
to scroll through the listed sensors.
(bypassed) and the
ZONE XX OFF
.
.
icon will turn on (the status
Press Status
ZONE XX ON
PROTEST
.