Chart Lock (*)
: Turns the chart function On/Off. When Chart Lock is On, the available zoom scales are only the
ones containing cartographic data. Instead when Chart Lock is Off, it is possible to zoom down
into zoom scales not covered by cartographic data after the last available zoom scale covered by
cartographic data. The DSI (Data Safety Indicator) window, if present, will show "NO CHART",
when an empty level is entered in the location of chart expansion mode.
Mixing Levels
: When the chart coverage at the current chart scale does not fill the entire display, the GPS Chart
Plotter draws the rest of the chart using charts from above and below the current scale. When this
function is turned on you will notice the display may redraw 2 to 3 times to show all the details.
When an empty level is entered, the message "No cartographic coverage" is shown on a window
in a corner of the chart display. The warning message is always displayed as long as the current
zoom has no data coverage.
12.0.11

Underwater Objects Settings

The following selections are used to control which Underwater Objects are shown on the
Chart page.
Underwater Object Limit : Selects the max depth value to display Underwater Objects. If value is set to 0Ft, the Underwater
Rocks
Obstructions
Diffusers
Wrecks
Choose the options: OFF (the object is not visible independently of the selected "Underwater Object
Depth Value"); ICON (the object icon is visible without tags, in the range selected from "Underwater
Object Depth Value" option); ICON+DEPTH (the object icon and tag is visible, in the range selected
from "Underwater Object Depth Value" option).
12.1

CUSTOMIZING CHART SETTINGS

The GPS Chart Plotter also allows you to customize items shown on the chart (discussed
in above sections) instead of using a pre-defined table discussed in Par. 12.0.4 Display
Mode.
1. Press [MENU], move the ShuttlePoint knob to highlight SETUP MENU and press [ENT].
2. Move the ShuttlePoint knob to highlight CHART CONFIGURATIONS and press [ENT]
or move the ShuttlePoint knob to the right.
CP390i and CPF390i
Objects are not shown on the charts. Menu options are grayed out. If value is more than 0Ft (i.e.
10Ft), in the Range from 0Ft to the selected value the Underwater Objects are displayed
according to their setting below.
:
Sets Off/Icon/Icon+Depth* the displaying of the Rocks.
:
Sets Off/Icon/Icon+Depth* the displaying of the Obstructions.
:
Sets Off/Icon/Icon+Depth* the displaying of Diffusers (Diffuser is a structure on an outfall
through which liquids are discharged. The structure will usually project above the level of the
outfall and can be an obstruction to navigation).
:
Sets Off/Icon/Icon+Depth* the displaying of Wrecks.
NOTE*