6.
Mark the lower anchoring point, remove the unit and drill the hole in the wall. Install the unit again and
attach the bottom attachment using steel a wall screw M6x70 mm, with the corresponding washer and plug.
7.
Check that the unit is properly secured.
Once the unit has been installed correctly, the connection process will begin.
Make the connections in the following order:
1.
Connection of accessories (optional)
2.
Connection of the ground connection (optional)
3.
AC connection
4.
DC connection
It is mandatory to follow the order described above. Do not switch on the power until you have made
all the connections and the unit is closed.

7.3. Opening the housing

To install the equipment it is not necessary to open the housing unless you wish to modify the ground
connection or install an accessory.