Unit description
DC input
Recommended power range of PV array (1)
Maximum input voltage
(2)
MPP voltage range
Operating voltage range
Minimum voltage for Pnom
Maximum short circuit current
Maximum inverter backfeed current to the
array
MPPT
Number of strings
Strings per MPP
Maximum input current
Maximum input current per string
AC output
Nominal power (up to 45 ºC)
Maximum continuous power
Max. temperature for nominal power
Maximum current
Maximum transient current
Maximum output fault current
Maximum output overcurrent protection
Rated voltage
Voltage range
Nominal frequency
Cosine of Phi
Adjustable cosine of phi
THD
Performance
Maximum efficiency
Euroefficiency
General data
Cooling system
Air flow
Weight
Measurements (height x width x depth)
Stand-by current
(4)
Nocturnal current
Operating temperature
Relative humidity (without condensation)
Protection rating
Markings
EMC and safety regulations
Grid connection regulations
Depending on the type of installation and geographical location.
(1)
temperatures.
(3)
For each ºC of increase, the output power is reduced by 1.8 %.
ABF2011IQE01_A - Installation and usage manual
4.6HF
5.2 ~ 6 kWp
550 V
125 ~ 500 V
125 ~ 550 V
146 V
37 A
0 A rms
1
3
3
33 A
17 A
4.6 kW
4.6 kW
58 ºC
(3)
26.2 A
26.2 A
30 A rms
230 V
122 ~ 285 V
50 / 60 Hz
1
Yes. Smax = 4.6 kVA
< 3 %
96 %
95.2 %
90 m
/h
3
25 kg
< 10 W
0 W
–25 ~ +65 ºC
0 ~ 100 %
IP65
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN
62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-21, VDE-AR-N 4105:2011-08, G59/2,
P.O.12.3, AS4777.2, AS4777.3, IEC 62116, IEC 61727, UNE 206007-1, ABNT NBR 16149, ABNT
NBR 16150, South African Grid code, Chilean Grid Code, Romanian Grid Code, Ecuadorian Grid
Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements
Never exceed this value. Consider the voltage increase of the panels 'Voc' at low
(2)
5HF
5.5HF
5.7 ~ 6.5 kWp
6 ~ 6.8 kWp
550 V
550 V
125 ~ 500 V
125 ~ 500 V
125 ~ 550 V
125 ~ 550 V
158 V
174 V
37 A
37 A
0 A rms
0 A rms
1
3
3
33 A
33 A
17 A
17 A
5 kW
5.5 kW
5 kW
5.5 kW
55 ºC
50 ºC
26.2 A
26.2 A
26.2 A
26.2 A
< 30 A rms (60 ms)
30 A rms
30 A rms
230 V
230 V
122 ~ 285 V
122 ~ 285 V
50 / 60 Hz
50 / 60 Hz
1
Yes. Smax = 5 kVA
Yes. Smax = 5.5 kVA
< 3 %
< 3 %
96 %
96 %
95.2 %
95.3 %
Forced ventilation
90 m
/h
90 m
3
25 kg
25 kg
470 x 360 x 180 mm
< 10 W
< 10 W
0 W
–25 ~ +65 ºC
–25 ~ +65 ºC
0 ~ 100 %
0 ~ 100 %
IP65
IP65
CE
(4)
Current from PV array.
Ingeteam
6HF
6.3 ~ 7 kWp
550 V
125 ~ 500 V
125 ~ 550 V
190 V
37 A
0 A rms
1
1
3
3
3
3
33 A
17 A
6 kW
6 kW
45 ºC
26.2 A
26.2 A
30 A rms
230 V
122 ~ 285 V
50 / 60 Hz
1
1
Yes. Smax = 6 kVA
< 3 %
96 %
95.3 %
/h
90 m
/h
3
3
25 kg
< 10 W
0 W
0 W
–25 ~ +65 ºC
0 ~ 100 %
IP65
11