Recording and playback after EIA-608t708 conversion, and down convert playback
In response to closed caption input data that complies with
the EIA-608 standard, record, play and output that data
after conversion to EIA-708 format. By performing down
convert playback, you can also play and output EIA-608
standard closed caption data.
However, settings are required for recording of EIA-608
standard closed caption data and for data output by down-
conversion playback.
SDSDI (line 21) input
EE output after EIA-608t708 conversion
In response to closed caption input data that complies with
the EIA-608 standard, output that data to EE after
conversion to EIA-708 format.
However, settings are required for output of EIA-608
standard closed caption data by down convert playback.
SDSDI (line 21) input
158
Ancillary Data
EIA-708 recording and playback
EIA-608 t708
conversion
For details, see "To record EIA-608-B standard closed
caption data in SDSDI line 21 signals after conversion to
the EIA-708-B standard (when the optional XDBK-103 is
installed)" (page 156), or "To record and playback EIA-
708-B standard closed caption data in HDSDI signals"
(page 155).
Down convert
playback
For details, see "To record EIA-608-B standard closed
caption data in SDSDI line 21 signals after conversion to
the EIA-708-B standard (when the optional XDBK-103 is
installed)" (page 156).
EIA-608 t708
conversion
Composite (line 21) output
HDSDI (VANC) output
SDSDI (line 21) output
Composite (line 21) output
HDSDI (VANC)
EE output
SDSDI (line 21) output