Sony XDS-PD1000 Operation Manual page 142

Professional media station
Hide thumbs Also See for XDS-PD1000:
Table of Contents

Advertisement

Alarm message in status
display area
Media Full!
TC EXT!
REGEN mode!
REC mode!
STOP ONCE!
Exit THUMBNAIL mode!
REMOTE!
No Media!
No Disc!
PORT SELECT mismatch.
Select PB Port.
Media Top!
Media End!
REC INHI.!
No EM Space
EM Full!
Illegal Operation!
Media is not Ready.
During recording operations
Alarm message in status
display area
REC INHI.!
Input Sig!
ILL. REC!
MEM. Full!
142
Troubleshooting
Description/action
Recording or copying is not possible because the internal storage is full.
Delete unneeded clips.
This appears when TCG on page P4 TC of the function menu is set to "EXT", and you try to preset
timecode or user bits by setting PRST/RGN to "PRESET".
Set TCG to "INT" (see page 50).
This appears when PRST/RGN on page P4 TC of the function menu is set to "TC" or "VITC", and
you try to preset timecode or user bits.
Set PRST/RGN to "PRESET" (see page 50).
Stop recording and try again.
This appears when an attempt is made to change media during recording or playback.
Stop the recording or playback and try the operation again.
This appears when an attempt is made to change media while the clip list screen is displayed.
Switch to the basic operation screen or the video monitor screen and try the operation again.
Press the REMOTE button, turning it off, to put this unit into local control mode.
Try again after loading an SxS memory card.
Insert a Professional Disc before operate.
This appears when you have selected an SxS memory card as media and have attempted to
specify the index picture by pressing the INDEX function button (F1) on page P5 OTHER of the
function menu.
An attempt has been made to execute a reverse search when the unit is stopped at the first frame
of the first clip after disc playback.
An attempt has been made to execute a forward search when the unit is stopped at the last frame
of the last clip after disc playback.
Set the Write-Inhibit tab on the disc so as to enable recording (see page 52).
This appears when any essence mark was not recorded because there is no space before and
after the desired position.
Delete unneeded shot marks 0 to 9 in the chapter thumbnail screen.
This appears when no more essence marks can be recorded.
Delete unneeded shot marks 0 to 9 in the chapter thumbnail screen.
This appears when an attempt is made to carry out an invalid operation.
The media is in the course of being mounted or has not been loaded.
Alarm message in video monitor screen Description/action
AUTO FORMATTING WAS NOT
COMPLETED. THE DISC WRITE
PROTECT TAB IS SET TO SAVE.
PLEASE EJECT DISC.
VIDEO INPUT SIGNAL DOES NOT
MATCH SYSTEM SETUP.
ENCODING DOES NOT SYNCHRONIZE
WITH REF VIDEO.
MEMORY FULL !!
Set the Write Inhibit tab on the disc so as to enable
recording (see page 52).
This appears when the signal that does not
correspond to the system frequency or the number of
lines set in this unit is being input, or when HD-SDI is
selected as a video input signal while setting the SD
signal recording.
Input a signal that matches the system frequency, or
change this unit's system frequency setting (see
page 43).
Check the signals being input to this unit.
Recording on a media is not possible because a
buffer overflow has occurred in the recording buffer
memory.

Hide quick links: