Removing The Hot-Swap Power Supply Cage - Lenovo ThinkServer TS100 Hardware Maintenance Manual

Types 6431, 6432, 6433, and 6434
Hide thumbs Also See for ThinkServer TS100:
Table of Contents

Advertisement

Removing the hot-swap power supply cage

This procedure applies only to server models that have hot-swap power-supplies.
To remove the power supply cage, complete the following steps:
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Turn off the server and all attached devices; then, disconnect all power cords
3. Unlock and remove the side cover (see "Removing the side cover" on page 62).
4. Remove both hot-swap power supplies (see "Removing a hot-swap power
5. Disconnect the cables from the power supply cage to the system board and all
6. Remove the four screws that secure the power supply cage to the chassis;
7. If you are instructed to return the power supply cage, follow all packaging
104
ThinkServer TS100 Types 6431, 6432, 6433, and 6434: Hardware Maintenance Manual
on page 57.
and external cables.
supply" on page 81).
Note: It might be helpful to lay the server on its side for the remainder of this
procedure.
internal components.
then, slide the cage toward the front of the server to disengage the retaining
clips from the top of the chassis and lift the cage out of the chassis.
instructions, and use any packaging materials for shipping that are supplied to
you.

Advertisement

Table of Contents
loading

This manual is also suitable for:

6431643264336434

Table of Contents