v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, ThinkServer TS100 Machine Types 6431, 6432, 6433, and 6434," on page 37
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System-error log message
ASM Reset -- reason unknown
ASM Reset due to x, Instruction Fault: y
ASM Reset due Watchdog timeout
ASM Reset was caused by restoring default
values
ASM Reset was initiated by the user
Configuration error recovery on the Inter-connect
network
CPU over temperature
DASD controller removal
DHCP failure,no IP@ assigned-
RETRYING!,rc=xxx,count=yyy
Dialback failed for userid w. Could not connect
at phone number x, y, z
ENET[eee] DHCP-
HstNme=a,DN=b,IP@=ccc.ccc.ccc.ccc
GW@=ddd.ddd.ddd.ddd, NMsk=fff.fff.fff.fff,
DNS1@=ggg.ggg.ggg.ggg,
DNS2@=hhh.hhh.hhh.hhh
ENET[eee] IP-Cfg:HstName=x,
IP@=ccc.ccc.ccc.ccc, GW@=ddd.ddd.ddd.ddd,
NetMsk=fff.fff.fff.fff
Failure reading an I2C device, possible bus
failure
Fan x Failure
Fan x Outside Recommended Speed
236
ThinkServer TS100 Types 6431, 6432, 6433, and 6434: Hardware Maintenance Manual
Action
Information only.
Information only.
Information only.
Information only.
Information only.
Information only.
1. Make sure that the fan sink has good airflow and is not
obstructed.
2. Reseat the following components:
a. Fan-sink cable
b. (Trained service technician only) Fan sink
1. Make sure that the mini-PCI-X adapter cable is not damaged.
2. Reseat the mini-PCI-X adapter cable.
3. Replace the mini-PCI-X adapter cable.
Information only.
Information only.
Information only.
Information only.
1. Reseat the following components:
a. AC power cords
b. Hot-swap power supplies, if any are installed
c. Power-supply cables on the system board
2. (Trained service technician only) Replace the system board.
1. Make sure that fan x is not obstructed.
2. Reseat the fan x cable.
3. Replace fan x.
1. Make sure that fan x is not obstructed.
2. Reseat the fan x cable.
3. Replace fan x.