Lenovo ThinkServer TS100 Hardware Maintenance Manual page 228

Types 6431, 6432, 6433, and 6434
Hide thumbs Also See for ThinkServer TS100:
Table of Contents

Advertisement

Table 12. Diagnostic messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 3, "Parts listing, ThinkServer TS100 Machine Types 6431, 6432, 6433, and 6434," on page 37 to determine
which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
201-807-xxx
Memory
210
ThinkServer TS100 Types 6431, 6432, 6433, and 6434: Hardware Maintenance Manual
Test
State
Memory Test
Aborted
Description
Action
Test canceled: the
1. Turn off and restart the system.
memory controller
2. Run the test again.
buffer free
request failed.
3. Make sure that the BIOS code is at the
latest level. The installed firmware level
is shown in the Diagnostic event log in
the Firmware/VPD section for this
component. For the latest level of
firmware, start firmware, go to
EasyUpdate or go to:
http://www.lenovo.com/support and
select your system to display a matrix
of available firmware.
4. Run the test again.
5. If the problem remains, collect the data
from the Diagnostic event log and send
it to Lenovo Service. For information
about contacting Lenovo Service, see
http://www.lenovo.com/support.

Advertisement

Table of Contents
loading

This manual is also suitable for:

6431643264336434

Table of Contents