Checkout procedure

The checkout procedure is the sequence of tasks that you should follow to
diagnose a problem in the server.

About the checkout procedure

Before you perform the checkout procedure for diagnosing hardware problems,
review the following information:
v Read the safety information that begins on page vii.
v The diagnostic programs provide the primary methods of testing the major
v When you run the diagnostic programs, a single problem might cause more than
v Before you run the diagnostic programs, you must determine whether the failing
v If the server is halted and a POST error code is displayed, see "Error logs" on
v For information about power supply problems, see "Solving power problems" on
v For intermittent problems, check the error log; see "Error logs" on page 133 and
components of the server, such as the system board, Ethernet controller, serial
ports, and hard disk drives. You can also use them to test some external devices.
If you are not sure whether a problem is caused by the hardware or by the
software, you can use the diagnostic programs to confirm that the hardware is
working correctly.
one error message. When this happens, correct the cause of the first error
message. The other error messages usually will not occur the next time you run
the diagnostic programs.
Exception: If multiple error codes or LEDs indicate a microprocessor error, the
error might be in a microprocessor or in a microprocessor socket. See
"Microprocessor problems" on page 153 for information about diagnosing
microprocessor problems.
server is part of a shared hard disk drive cluster (two or more servers sharing
external storage devices). If it is part of a cluster, you can run all diagnostic
programs except the ones that test the storage unit (that is, a hard disk drive in
the storage unit) or the storage adapter that is attached to the storage unit. The
failing server might be part of a cluster if any of the following conditions is true:
– You have identified the failing server as part of a cluster (two or more servers
sharing external storage devices).
– One or more external storage units are attached to the failing server and at
least one of the attached storage units is also attached to another server or
unidentifiable device.
– One or more servers are located near the failing server.
Important: If the server is part of a shared hard disk drive cluster, run one test
at a time.
page 133. If the server is halted and no error message is displayed, see
"Troubleshooting tables" on page 147 and "Solving undetermined problems" on
page 245.
page 243.
"Diagnostic programs and messages" on page 163.
145
Chapter 5. Diagnostics