5.6

Cooling Module Maintenance

5.6.1

Notes on Cooling Module Maintenance

5-16
Figure 5-13: Inserting the PSU Module
Secure the PSU to the subsystem by fastening the
retention screw through the PSU extraction handle.
Replace the power cord that connects the PSU to the
main power source.
Power on the PSU by flipping its power switch.
Ensure the replacement PSU is working properly
by checking its LED. The LED should light constant
green when powered on.
Redundant cooling modules: The subsystem is equipped
with four (4) cooling blowers, two (2) within each cooling
module. These cooling modules control the operating
temperature within the chassis and therefore their working
integrity should be maintained at all times.
Although the cooling modules are fully redundant, it is not
advisable to run the EonStor subsystem with fans in a single
PSU module for an extended period of time. If the cooling
fans in the only remaining module fail, the subsystem will
quickly overheat.
Detecting a failed cooling module: If a cooling module
fails, the LEDs located at the rear-facing faceplate of the
PSU module, an audible alarm, the firmware utility, the
RAIDWatch manager software, or the Configuration Client
utility can notify you.