Take off the developer sleeve.
* Procedure for replacing an oil seal:
P.12-32 "Fig.12-63 "
[A-6]
Mixer
(1)
Discharge the developer material
(
P.12-16 "[A-2] Developer material").
(2)
Take off the developer sleeve
(
P.12-18 "[A-5] Developer sleeve").
(3)
Front side: Remove the following parts
installed on the shaft of each mixer in order:
E-ring, bushing-1 and bushing-2.
* Procedure for replacing an oil seal:
P.12-32 "Fig.12-63 "
(4)
Rear side: Remove the following parts
installed on the shaft of each mixer in order:
E-ring, gear, bearing and oil seal.
* Procedure for replacing an oil seal:
P.12-32 "Fig.12-63 "
e-STUDIO281c/351c/451c DEVELOPER UNIT
Developer sleeve
Bushing-2
E-ring
12 - 20
Fig.12-26
E-ring
Bushing-1
Fig.12-27
E-ring
Gear
Fig.12-28