Toshiba e-STUDIO281c Service Manual page 267

Hide thumbs Also See for e-STUDIO281c:
Table of Contents

Advertisement

[P]
Temperature/humidity sensor (S19)
(1)
Take off the front cover
(
P.2-25 "[A] Front cover").
(2)
Take off the front lower cover
(
P.2-26 "[E] Front lower cover")
(3)
Take off the inner tray (
tray").
(4)
Take off the left cover
(
P.2-29 "[K] Left cover").
(5)
Remove 2 screws and take off the left inner
cover.
(6)
Disconnect 1 connector and release 2
latches. Then take off the temperature/
humidity sensor.
[Q] Ozone filter
(1)
Remove 1 screw and take off the cover.
(2)
Take off the ozone filter.
June 2005 © TOSHIBA TEC
P.2-26 "[C] Inner
Latch
Screw
11 - 23
Left inner cover
Fig.11-45
Temperature/Humidity sensor
Fig.11-46
Ozone filter
Cover
Fig.11-47
e-STUDIO281c/351c/451c DRUM RELATED SECTION
Screw
11