4 - 22 DS4800 Series Corded Digital Imager Product Reference Guide
Decode Session Timeout
Parameter # 136
This parameter sets the maximum time decode processing continues during a scan attempt. It is
programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from
G, Numeric Bar Codes
For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and
5 bar codes. To correct an error or change the selection, scan
Decode Session Timeout
Timeout Between Decodes, Same Symbol
Parameter # 137
Use this option in Continuous Bar Code Read mode to prevent the speaker from continuously beeping when a
symbol is left in the imager's field of view. The bar code must be out of the field of view for the timeout period
before the imager reads the same consecutive symbol. It is programmable in 0.1 second increments from 0.0
to 9.9 seconds. The default interval is 0.5 seconds.
To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric
bar codes from
Appendix G, Numeric Bar Codes
increments.
that correspond to the desired on time. Enter a leading zero for single digit numbers.
Cancel on page G-2
that correspond to the desired interval, in 0.1 second
Timeout Between Decodes, Same Symbol
Appendix
.