Continuous Bar Code Read; Decode Session Timeout - Motorola symbol ds9808 Reference Manual

Hide thumbs Also See for symbol ds9808:
Table of Contents

Advertisement

Continuous Bar Code Read

Parameter # F1 89h
Enable this to report every bar code while the trigger is pressed.
NOTE Motorola strongly recommends enabling
Mode can cause accidental decodes when more than one bar code is in the imaging engine's field of view.
*
Disable Continuous Bar Code Read
(0h)

Decode Session Timeout

Parameter # 88h
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in
0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from
Numeric Bar Codes
that correspond to the desired on time. Enter a leading zero for single digit numbers. For
example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar
codes. To correct an error or change the selection, scan Cancel on
Decode Session Timeout
User Preferences & Miscellaneous Digital Scanner Options 4 - 27
Picklist Mode on page 4-26
Enable Continuous Bar Code Read
page
with this feature. Disabling Picklist
(1h)
D-2.
Appendix D,

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents