I t e m
Radiator:
Type
Width/height/thickness
Radiator cap opening pressure
Radiator capacity
Reservoir tank capacity
Thermostatic valve:
Valve opening temperature
Valve full open temperature
Valve full open lift
260/ 300 / 400 cc
Standard
Cooling fin with electric fan
260 /300: 288/238/42 mm
400: 360/246/68 m
110-140kPa (1.1-1.4kg/cm
1.1-1.4bar)
2 L
0 .35 L
70 .5- 73 .5℃
85 ℃
3 mm
CHAPTER 3 ENGINE
ATV SERVICE MANUAL09.0
Limit
...
...
...
2
,
...
...
PAGE. 3A-
6