4.Starter relay

Disconnect the relay unit coupler from
the wire harness.
Connect the pocket tester (Ωx1) and
battery (12V) to the relay unit coupler
terminals.
Battery (+) lead→
Green/Yellow terminal
Battery (-) lead→
Yellow/Red terminal
Check the starter relay for continuity.
Test (+) lead →
Test (-) lead →
terminal
CONTINUITY

5. .Starting circuit cut-off relay

Disconnect the starting circuit cut-off
relay coupler from the wireharness.
Connect the pocket tester (Ωx1) and
battery (12V) to the starting circuit cut-off
relay coupler terminals.
Battery (+) lead→ terminal
Battery (-) lead→ terminal
Check the starting circuit cut-off relay
for continuity.
Test (+) lead →
Test (-) lead →
terminal
terminal
terminal
ATV SERVICE MANUAL 09.0
WARNING
A wire used as a jumper lead
must have the equivalent
capacity as that of the battery
lead or more, otherwise it
may burn.
This
check
is
produce sparks, so be sure
that no flammable gas or fluid
is in the vicinity
Replace the starter replay
Replace
the
starting
cut-off relay
CHAPTER 8 ELECTRICAL CTRICAL PAGE 8- 18